These 2-way packless direct acting valves are suitable for steam flows to 100 lbs. per hour and are available with sil brazed union ends per MIL-F-1183. All are supplied with manual operating devices and meet the Hi-Shock requirements of MIL-S-901. No minimum operating pressure differential is required.
| Operation | Normally closed (valve closed when de-energized,open when energized) |
| Pipe Sizes | 3/8” and 1/2” sil brazed union ends per MIL-F-1183 |
| Valve Body | Forged Brass |
| Valve Seat | Stainless Steel (300 Series) |
| Solenoid Construction | Internal parts in contact with fluid are of 300 Series and 400 Series stainless steel |
| Solenoid Enclosures | Navy watertight Hi-Shock(15-foot submersible) |
| Electrical | Standard 115 volts, AC, 60 Hz.(Consult factory for other voltages) |
| Installation | AV224593 valve must be mounted with solenoid vertical and upright. AV174565 valves may be mounted in any position without affecting operation |
These valves meet the steam solenoid valve requirements covered in MIL-R-16743, “Refrigerating Plants and Systems, Mechanical; and Refrigerating System Components – Dichlorodifluoromethane R12 – Naval Shipboard,” paragraph 3.6.16, the refrigeration plant and systems specification for Naval shipboard use. Valves listed below may be used for many other shipboard applications.